« Previous
Next »
Journal of Dairy Science
Volume 92, Issue 1
, Pages
35-48
, January 2009
Glycosylation and expanded utility of a modified whey protein ingredient via carbohydrate conjugation at low pH
-
Ionization mass spectrometry chromatography data, in duplicate, illustrating β-LG peaks from nonheated modified whey protein concentrate (mWPC) samples and lactosylated β-LG from heated mWPC samples.
Ionization mass spectrometry chromatography data, in duplicate, illustrating β-LG peaks from nonheated modified whey protein concentrate (mWPC) samples and lactosylated β-LG from heated mWPC samples.
-
A) SDS-PAGE banding pattern of whey protein and whey protein-carbohydrate conjugates. Lane 1 = marker protein; lane 2 = commercial whey protein concentrate (cWPC); lane 3 = modified whey protein conce
A) SDS-PAGE banding pattern of whey protein and whey protein-carbohydrate conjugates. Lane 1 = marker protein; lane 2 = commercial whey protein concentrate (cWPC); lane 3 = modified whey protein concentrate (mWPC); lane = heated mWPC; lane 5 = heated mWPC-dextran (DX) 35; lane 6 = heated mWPC-DX100. Samples in lanes 4, 5, and 6 were heat treated (100°C, 2
h) under dry conditions. All samples were initially prepared at pH 3.5, before electrophoresis, except for cWPC, which was prepared at pH 6.6. B) SDS-PAGE glycoprotein staining pattern of whey protein and whey protein-dextran test samples as loaded in the same order. -
A) Apparent viscosity of reconstituted nonheated modified whey protein concentrate (mWPC; 7% protein, wt/vol) with or without dextran (DX) and prepared at a 2:1 ratio, over the shear rate range from 0A) Apparent viscosity of reconstituted nonheated modified whey protein concentrate (mWPC; 7% protein, wt/vol) with or without dextran (DX) and prepared at a 2:1 ratio, over the shear rate range from 0.1 to 500
s−1 at 25°C. Error bars represent 1 standard deviation from the mean; B) apparent viscosity of reconstituted heated (100°C, 2h) mWPC (7% protein, wt/vol) with or without DX and prepared at a 2:1 ratio, over the shear rate range of 0.1 to 500
s−1 at 25°C. Error bars represent 1 standard deviation from the mean. -
A) Small amplitude oscillatory shear data for reconstituted nonheated modified whey protein concentrate (mWPC; 7% protein, wt/vol) with or without dextran (DX) and prepared at a 2:1 ratio. Closed symbA) Small amplitude oscillatory shear data for reconstituted nonheated modified whey protein concentrate (mWPC; 7% protein, wt/vol) with or without dextran (DX) and prepared at a 2:1 ratio. Closed symbols indicate G′ values and open symbols indicate G″ values. Error bars represent 1 standard deviation from the mean; B) small amplitude oscillatory shear data for reconstituted mWPC (7%, wt/vol) with or without DX and prepared at a 2:1 ratio, after dry heat treatment at 100°C for 2
h. Closed symbols indicate G′ values and open symbols indicate G″ values. Error bars represent 1 standard deviation from the mean. -
Plot of creaming index values for 5mg/mL protein solutions of commercial whey protein concentrate (cWPC), modified whey protein concentrate (mWPC), and heated mWPC, mWPC-dextran (DX)100, mWPC-DX35 disPlot of creaming index values for 5
mg/mL protein solutions of commercial whey protein concentrate (cWPC), modified whey protein concentrate (mWPC), and heated mWPC, mWPC-dextran (DX)100, mWPC-DX35 dispersions, prepared at a 2:1 ratio, measured after 1
wk at ambient temperature. Error bars represent 1 standard deviation from the mean. All samples were prepared at pH 3.5 except for cWPC, which was prepared at pH 6.6. a–eDifferent letters indicate significant differences (P
<
0.05). -
Scanning electron micrographs of modified whey protein concentrate (mWPC) and mWPC-dextran (DX) samples (5.6% protein, wt/vol). A) mWPC, 2,500× magnification, scale bar = 10μm; B) mWPC-DX100, 2:1 ratiScanning electron micrographs of modified whey protein concentrate (mWPC) and mWPC-dextran (DX) samples (5.6% protein, wt/vol). A) mWPC, 2,500× magnification, scale bar = 10
μm; B) mWPC-DX100, 2:1 ratio, 2,500×, scale bar = 10
μm; C) mWPC, 15,000×, scale bar = 1
μm; and (D) mWPC-DX100, 2:1 ratio, 15,000×, scale bar = 1
μm. -
Changes in the water-holding capacity of nonheated and heated modified whey protein concentrate (mWPC; 5.6% protein) prepared in the presence and absence of dextran (DX, 2:1 ratio) at pH 3.5. a–dDiffeChanges in the water-holding capacity of nonheated and heated modified whey protein concentrate (mWPC; 5.6% protein) prepared in the presence and absence of dextran (DX, 2:1 ratio) at pH 3.5. a–dDifferent letters indicate significant differences (P
<
0.05).
1 Paper no. FSR-02-42 of the Journal Series of the Department of Food Science, North Carolina State University, Raleigh 27695-7624.
2 The use of trade names in this publication does not imply endorsement by the North Carolina Agricultural Research Service of products named, or criticism of similar ones not mentioned.
PII: S0022-0302(09)70307-8
doi: 10.3168/jds.2008-1263
© 2009 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Dairy Science
Volume 92, Issue 1
, Pages
35-48
, January 2009